Customization: | Available |
---|---|
Customized: | Customized |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. |
Parameter name |
Unit |
Main technical parameter |
Notes |
1 | Arc furnace type | Semi-closed stationary type | Semi- closed operation | |
2 | Rated power | kVA | 33000 | 11000kVA×3 (single phase) |
3 | Electrode diameter |
mm | φ1350mm | |
4 | Electrode stroke |
mm | 2200mm | |
5 | Tube quantity |
25 | DN400 | |
6 | Tap hole quantity |
2 | ||
7 | Slag hole quantity |
2 | ||
8 | Hydraulic system working pressure |
MPa | 11 | Water glycol |